Drager Evita 4 Ventilator

Date Recording and Transmission:

HeartStart Event Review Data management software (optional) for download and review of Software: data retrieved through defibrillator’s infrared data port

The Dräger Evita 4 is a ventilator for every patient population. The Evita 4 was designed to meet the demanding requirements of the ICU environment by improving the interactions between patient, ventilator and clinician. The functional touch screen continually provides the clinician information on ventilator settings, patient measurements and advanced trending capabilities which enhances the operation of the device. Unique features and modalities such as AutoFlow™ and APRV are standard on all Evita 4 ventilators.
 

AutoFlow and APRV are standard on all Evita 4 ventilators

Universal mode for ventilation and weaning: PCV+/ BIPAPTM*pump, neutralization system and mobile cart optional


User Interface:

Instructions: Detailed voice prompts and visual icons guide responder through use of the defibrillator

CPR coaching: Voice coaching for adult and infant/child CPR provides instructions and audio cues for the appropriate number, rate and depth of chest compressions, as well as for each breath

Controls: Green On/Off button, blue i-button, orange Shock button, optional Infant/Child key

Indicators: Ready light, blue i-button, caution light, illuminated pads, icons, Shock button lights up when shock is advised

Model Number Evita 4
Usage/Application ICU
Brand Drager
Modes of ventilation SIMV+VG,SIPPV+VG,PSV+VG
Display Type LCD
Breathing Frequency ftotal,fspon,fmand. (0 to 300/bpm)
Tidal Volume Inspired VT,expired VT,VTASB (VTPS) (0 to 3999 mL)
I deal in Second Hand Only
Capnography 0 to 100 mmHg
Trends FiO2,MV,VT,f,PEEPi,R,C,etCO2
CO2 Production 0 to 999 mL/min,STPD
Dead Space Ventilation 0 to 99%
Airway Pressure Peak pressure,plateau pressure,mean pressure,PEEP,min. pressure (0 to 99 mbar/cmH2O)
O2 Concentration (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
O2 Saturation SpO2,pulse
Data Stored First 15 minutes of ECG and the entire incident's events and analysis decisions
Waveforms Airway pressure-time,flow-time,volume-time
Infrared Wireless transmission of event data to a Smartphone or PC,using the IrDA protocol
Minute Volume MV,MVspont,MVleak (0 to 99 L/min)
Resistance 0.0 to 600 mbar/L/s)(cmH2O/L/s
Breathing Gas Temprature 18 to 51 deg C
Compliance 0.0 to 300 mL/mbar)(mL/cmH2O
Loops Paw-V,V-Flow,Flow-Paw